http://ASNSERVICES.CO.IN
PARKINGMANAGEMENTSYSTEMS 5a549ebce2f63f0b7806eedd False 57 12
OK
background image not found
Found Update results for
'installation ambiance'
5
Loop Detector Supplier in Delhi NCR Technical Data: Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10 mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide"). - Operation and Indication: While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered. - Output Relay: The relay2 is pulse output. If DIP7 is "OFF" site, when a vehicle is detected passing over the inductive loop, the relay is energized( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. If DIP7 is "ON" site, when a vehicle is detected departing the loop, the relay is energized ( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. The relay 1 is presence output. When a vehicle is detected passing over the inductive loop, the relay is energized( Pin5 and Pin6 are shorted) until the vehicle is detected departing the loop. - Presence Time: The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop, the presence mode is set with DIP8 Switch and is configured as follows: OFF:Limited Presence ( 10 minutes), ON:Permanent Presence. - Reset Switch : The detector automatically tunes to the inductive loop connected to it when the power is applied, whether on initial installation or after any break in power supply. Should it be necessary to re-tune the detector, as may be required after changing any of the switches or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle.
Boom Barrier Supplier in Delhi NCR Automatic boom barrier offers security at the exit and the entry points of industrial unit, offices, corporate houses, residential areas, parking lots, toll tax plazas etc. Automatic barrier can be used to successfully control pedestrian and vehicle traffic. It can be used achieve better security. High performance Boom Barriers offered by ASN Services Pvt. Ltd are suitable for any type of installation ambiance. The wide range of lengths and accessories available ensures that all installation requirements are met. All models are equipped with a facility of manual operation in the event of power failure and battery back-up capability in selected models. • Wide range of models to suit various applications like car parking sites, condominiums, toll collection & Industrial entrance • Available for boom length up to 3 m. Opening up to 8 m can be covered. • Highly compact in size has an extremely silent operation • Sturdy steel structure with scratch-proof coating resistant to harsh weather conditions • Integration possible with wide range of accessories and all kinds of access control systems • Extremely reliable and maintenance free. Tested and distributed all over the world • Manual release in case of power failure. Battery backup facility in select models Automatic boom barrier Offers security at the exit and the entry points of industrial unit, offices, corporate houses, residential areas, parking lots, toll tax plazas etc. Automatic barrier can be used to successfully control pedestrian and vehicle traffic. It can be used achieve better security. High performance Boom Barriers offered by ASN Services Pvt Ltd. are suitable for any type of installation atmosphere. The wide range of lengths and accessories available ensures that all installation requirements are meet. All models are outfitted with a facility of manual operation in the occurrence of power failure and battery back-up capability in selected models.
Hydraulic Bollards Supplier In Delhi Ncr FEATURE: Hydraulic movement: The most reliable technology for intense temperatures and weather conditions. Built–in hydraulic pump in the bollard: These bollards have many advantages, particularly in installations on locations with severe winter temperatures or when the installation requires a considerable distance(up to 80 meters) between the Bollard and the control unit. Patented system for the protection of handling: To maximize the reliability of operations due to impact by vehicles on the cylinder that is put in motion. Wide range of optional configurations: Custom colors, flashing lights integrated into the head, intermittent sound signal, heat resistance installations in locations with harsh winter temperatures, UPS unit for operation in the temporary occurrence of power failure, equipment control, equipment accident prevention (see accessories and optional items).
Automatic Boom Barrier Supplier/Manufacturer in Delhi NCR Automatic boom barrier offers security at the exit and the entry points of industrial unit, offices, corporate houses, residential areas, parking lots, toll tax plazas etc. Automatic barrier can be used to successfully control pedestrian and vehicle traffic. It can be used achieve better security. High performance Boom Barriers offered by ASN Services Pvt Ltd are suitable for any type of installation ambiance. The wide range of lengths and accessories available ensures that all installation requirements are met. All models are equipped with a facility of manual operation in the event of power failure and battery back-up capability in selected models. • Wide range of models to suit various applications like car parking sites, condominiums, toll collection & Industrial entrance • Available for boom length up to 3 m. Opening up to 8 m can be covered. • Highly compact in size has an extremely silent operation • Sturdy steel structure with scratch-proof coating resistant to harsh weather conditions • Integration possible with wide range of accessories and all kinds of access control systems • Extremely reliable and maintenance free. Tested and distributed all over the world • Manual release in case of power failure. Battery backup facility in select models
Loop Detector Supplier in Delhi NCR Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide").
1
false